At Nordenflow, we supply solenoid valves for pneumatic and hydraulic systems used in control, automation, and safety applications.
Solenoid valves control the flow of air or fluid by converting electrical signals into mechanical action, directly affecting system response time and operational reliability.

We focus on fast response, application support, and access to proven technologies like the Maxseal ICO2S, ICO3S and ICO4S series. We help customers ensure safe and consistent operation in demanding environments.
Our solenoid valves are engineered for high reliability in pneumatic and fluid control systems, including actuator applications and safety loops.
Available in stainless steel and other corrosion-resistant materials, they are suitable for harsh environments and continuous operation.

When You Need Solenoid Valves

Solenoid valves are required when fast, reliable control of air or fluid flow is critical for system performance, automation, or safety functions.

Electrical Signal Must Control Flow

When system operation requires converting electrical signals into immediate valve actuation for control or automation.

Fast Response or Shutdown is Required

Critical in emergency shutdown (ESD) systems and safety applications where rapid valve actuation is essential.

Unstable or Inconsistent System Behavior

When valve response is delayed, inconsistent, or unreliable due to improper signal or control components.

Pneumatic or Hydraulic Actuation Control

Used to control air or hydraulic supply for actuators, enabling automated valve operation.

Safety and SIL Requirements

Required in safety systems where reliability and compliance with SIL standards are essential.

Replacement or Upgrade

When existing solenoid valves fail, leak, or no longer meet system performance or safety requirements.

What We Supply

We supply solenoid valve solutions for pneumatic and hydraulic systems, configured for control, automation, and safety applications.

Our range includes products from :contentReference[oaicite:0]{index=0} brands such as :contentReference[oaicite:1]{index=1}, :contentReference[oaicite:2]{index=2}, and :contentReference[oaicite:3]{index=3}, selected based on system requirements, response time, and safety performance.

Pneumatic and Hydraulic Solenoid Valves

Solutions for controlling air and hydraulic flow in automation systems, actuator control, and process applications.

High-Performance Solenoid Valves (Maxseal Series)

Designed for demanding environments requiring high reliability, fast response, and long service life in control and safety systems.

ICO3S & ICO4S Solenoid Valves

:contentReference[oaicite:4]{index=4} ICO3S and ICO4S series are widely used in critical applications such as ESD systems and valve automation.

→ Fast switching, high reliability, suitable for harsh and hazardous environments

Safety and SIL Applications

Solenoid valves configured for safety systems with requirements for reliability, redundancy, and compliance with SIL standards.

System Integration

Integration with actuators, control systems, and instrumentation to ensure reliable operation and consistent system performance.

Replacement and Retrofit Solutions

Direct replacement options for existing systems, including upgrades for improved reliability and performance.

IMI Maxseal  ICO3S - ICO4S - Solenoid Poppet Valve

Engineering Scope

Solenoid valve performance is defined by response time, pressure conditions, and reliable signal actuation within control and safety systems.

Response Time

Switching speed is critical in control and safety systems, particularly for emergency shutdown (ESD) applications.

Operating Pressure Range

Selection depends on available air or hydraulic pressure to ensure reliable actuation without delay or failure.

Flow Capacity (Cv)

Valve sizing must ensure sufficient flow capacity for actuator operation and system response requirements.

Electrical Parameters

Voltage, power consumption, and coil characteristics must match system requirements for stable operation.

Environmental Conditions

Temperature, hazardous area classification (ATEX), and protection ratings influence material and design selection.

Functional Safety (SIL)

Solenoid valves used in safety systems must meet required SIL levels for reliability and fail-safe operation.

Incorrect selection of solenoid valves can lead to delayed response, unstable operation, or failure of safety systems.

Features & Standards

Function: 2/2, 3/2, 5/2, 5/3 way configurations
Operation: Direct acting / Pilot operated

Media: Air, gas, hydraulic oil
Applications: Pneumatic and hydraulic systems

Operating Pressure: Vacuum to high pressure (depending on design)
Flow Capacity: Cv-based sizing

Voltage: 24V DC, 110V / 230V AC
Signal: Electrical control input

Protection: IP65 / IP67 / IP68
Hazardous Area: ATEX certified options

Body Materials: Brass, stainless steel
Seals: NBR, FKM, EPDM (application dependent)

Standards: IEC, EN, ISO
Certifications: ATEX, SIL (application dependent)

Maxseal Series: ICO3S / ICO4S
Application: ESD, safety systems, harsh environments

Solenoid Valve Manifold Solutions

For high-integrity ESD and automation systems, Nordenflow supports solenoid valve manifold assemblies designed for redundancy, reliability, and integrated control.

These systems combine multiple solenoid valves into a single engineered unit, reducing installation complexity while improving system performance and safety.

Modular Manifold Design

Configurable manifold assemblies in aluminum or stainless steel, designed for flexible system integration and maintenance.

Redundant Configurations

Designed for safety-critical systems using configurations such as 1oo2 and 2oo3 to improve system reliability and fault tolerance.

Integrated Control Components

Integration of isolation valves, pressure regulators, and gauges within a single unit for simplified installation and operation.

Actuator Control Integration

Designed for pneumatic and hydraulic actuator control in automation and shutdown systems.

Designed for Demanding Environments

Suitable for hazardous and critical applications requiring ATEX certification and SIL compliance.

Manifold solutions reduce installation complexity, improve reliability, and support structured safety system design in ESD and automation applications.

Available as part of complete solenoid valve and instrumentation solutions.

IMI Maxseal  RVM - Redundant Valve Manifold

Applications

Solenoid valves and manifold systems are used across control, automation, and safety applications where reliable signal actuation and system response are critical.

Valve Actuator Control

Solenoid valves control pneumatic and hydraulic actuators, enabling automated valve operation in industrial systems.

Process Control Systems

Used within control loops to manage air and fluid signals, ensuring stable and responsive system performance.

Emergency Shutdown (ESD) Systems

High-reliability solenoid valves and manifold assemblies are used to ensure rapid and dependable shutdown in critical situations.

Safety Instrumented Systems (SIS)

Redundant manifold configurations (e.g., 1oo2, 2oo3) support SIL-rated safety functions and improve system reliability.

Integrated Manifold Systems

Manifold assemblies combine multiple solenoid valves and control components into a single unit, reducing installation complexity and improving maintainability.

System Upgrade and Replacement

Replacement of existing solenoid valves or integration of manifold systems to improve performance, reliability, and safety compliance.

Define Your Solenoid Valve and Control System Requirements

Share your application details to select the right solenoid valve or manifold solution based on response time, pressure conditions, and safety requirements.

• Application type (control, ESD, safety system)

• Pneumatic or hydraulic system details

• Required response time and switching behavior

• Operating pressure and flow conditions

• Environmental conditions (hazardous area, temperature)

• SIL, redundancy (1oo2 / 2oo3), or manifold requirements